What is a Part A Structural Inspection Checklist?
A Part A Structural Inspection Checklist is a form that contains a complete list of structural and standard requirements that must be evaluated to ensure that the structure meets regulatory, safety, and quality standards. The structural checklist focuses on the overall condition of the building's structural members and determines whether they comply with design and UK laws.
The checklist guarantees that all key elements are checked before moving on to the next construction phase.
Compare this Part A Structural Inspection Checklist to paper-based forms created from Word, Excel, or PDF
Use this Part A Structural Inspection Checklist template for free.
Structural assessment checklist: structural members that are required to be assessed in Part A?
Approved Document A mandate designs standards for the structural stability and safety of buildings and provides instructions to avoid compromising the integrity of adjacent structures. To ensure that all structural members follow such standards, inspections must be conducted on them. Here are the following structural members that require inspection.
Foundation and Groundwork
These critical elements are required to be assessed to guarantee that they effectively transfer loads into the ground. Loads should transfer without excessive settlement, instability, or failure. Inspections include checking site excavation, footing dimensions, rebar installation, and verifying if bearing capacity and concrete cover meet minimum requirements.
Columns and Vertical Supports
Columns and vertical supports are critical members since they primarily facilitate the building's vertical loads. Thus, these structural members must be checked for alignment and continuity to ensure full functionality. Inspections include verifying if columns, reinforcement, splices, laps, & ties are correct and checking if formwork alignment, stability, and concrete quality are acceptable.
Beams, Slabs & Structural Framing
Beams, Slabs, and a building's structural framing are responsible for carrying imposed loads and distributing them equally throughout the structure. These structural elements are designed to provide balance to the overall building. Inspecting these members ensures that this balance is achieved, avoiding deflection issues and maintaining the building's overall performance. Inspection includes checking if beams and slabs are in accordance with the approved design, reinforcements are verified before pouring, openings and penetrations are coordinated, and concrete strength test results are available.
Structural inspection checklist: stages of Part A structural inspections?
Structural Inspections are not a one-time thing. They need to be conducted more than a few times to ensure that when the built structure is finished, it is rigid and sound and complies with the UK regulatory standards and mandates. To best guide inspectors, here are general stages where a structural inspection is necessary.
Initial Inspection
The initial inspection is conducted when the major structural elements of the building—those mentioned in the previous section—have been installed and built. This allows stakeholders to have an early outlook if the building is already committing to the building standards and requirements, which prompts immediate action for findings. This inspection helps avoid costly repairs or rework during the later stages of the construction.
Follow-up Inspection
Follow-up inspections are often conducted to determine if the findings of the initial and final inspections were addressed. This remedial inspection helps stakeholders focus on addressing findings that were not resolved since the primary inspection (initial or final) and ensure that they are closed before the next follow-up inspection.
Final Inspection
Final Inspection is conducted when the building is complete. It is a final confirmation that the building is constructed in accordance with its design and is aligned with approved document A. This final inspection will also serve as evidence during audits that the building was evaluated before occupancy.
Frequently Asked Questions
Why is this the best Structural Inspection Checklist template?
Sitemate’s Structural Inspection Checklist is the best template for structural inspections because it’s trusted by thousands of construction and engineering companies. Pre-configured to follow industry best practices, it ensures accurate, consistent inspections and is simple and efficient for any worker to use.
Is this template compliant with UK Building standards?
Yes – this template is fully configured to comply with UK Building Standards. Trusted by certified contractors across the construction and engineering industry, it streamlines inspections, ensures regulatory compliance, and simplifies documentation for all building projects.
Can I edit this Part A Structural Inspection Checklist Template for my project or company?
Yes – the template is fully editable with intuitive drag-and-drop functionality. You can create unlimited document layouts using tables, formulas, sketches, photos, and more to capture any type of data. Customize it further with your company logo, headers, and other key elements—all powered by Dashpivot’s robust template builder.
On which platforms can the structural inspection checklist be accessed?
This template works seamlessly across all devices—desktop, tablet, and mobile. You can complete Part A Structural Inspection Checklist forms in the office or directly on-site. Once submitted, records can be generated or exported as PDF or CSV, giving you the flexibility of Word, Excel, and PDF with the efficiency of modern software.
Other popular templates you can use and edit for free

Part A Structural Design Checklist
Streamline the process of inspecting important structural design elements needed for a building to meet standards.

Retaining Wall Inspection Report
Verify if the retaining walls and their elements are within the permitted design limitations and comply with UK Building Regulations.

Framing Inspection Checklist
Ensure that the framing elements are built with the highest quality and comply with UK regulations.
This Design Review Form was generated with Dashpivot
Ensure that the structural members of a building are in accordance with its design and UK regulatory standards. This Part A Structural Inspection Checklist allows stakeholders to easily discover flaws in the structural design, which leads to immediate decision-making and remediation.
- Complete, edit, and review the EV charging infrastructure report on any device.
- Export reports as perfectly formatted PDF documents with your company logo.
- Invite internal and external parties to see, edit, and review the inspection forms online.
- Include necessary attachments to provide more detailed information on findings.
Sitemate builds best-in-class software tools for built world companies.